{"id":2107,"date":"2026-07-31T12:00:00","date_gmt":"2026-07-31T12:00:00","guid":{"rendered":"https:\/\/www.madeforsilicone.com\/?p=2107"},"modified":"2026-08-01T14:41:28","modified_gmt":"2026-08-01T06:41:28","slug":"lsr-overmolded-respiratory-device-components","status":"publish","type":"product","link":"https:\/\/www.madeforsilicone.com\/vi\/product\/lsr-overmolded-respiratory-device-components\/","title":{"rendered":"C\u00e1c b\u1ed9 ph\u1eadn c\u1ee7a thi\u1ebft b\u1ecb h\u00f4 h\u1ea5p \u0111\u01b0\u1ee3c \u0111\u00fac ph\u1ee7 b\u1eb1ng LSR"},"content":{"rendered":"<h2>T\u1ed5ng quan v\u1ec1 s\u1ea3n ph\u1ea9m<\/h2>\n<p>Respiratory-device subcomponents may use a rigid housing for alignment and an LSR layer for sealing, cushioning or soft contact. The assembly interface, fluid or air path, cleaning exposure and material requirements should be reviewed before mold design.<\/p>\n<p><strong>C\u00e1c b\u1ed9 ph\u1eadn c\u1ee7a thi\u1ebft b\u1ecb h\u00f4 h\u1ea5p \u0111\u01b0\u1ee3c \u0111\u00fac ph\u1ee7 b\u1eb1ng LSR<\/strong> S\u1ea3n ph\u1ea9m \u0111\u01b0\u1ee3c cung c\u1ea5p d\u01b0\u1edbi d\u1ea1ng linh ki\u1ec7n B2B t\u00f9y ch\u1ec9nh d\u00e0nh cho c\u00e1c ch\u01b0\u01a1ng tr\u00ecnh OEM, ODM v\u00e0 gia c\u00f4ng theo h\u1ee3p \u0111\u1ed3ng. \u0110\u00e2y kh\u00f4ng ph\u1ea3i l\u00e0 m\u1eb7t h\u00e0ng b\u00e1n l\u1ebb c\u00f3 s\u1eb5n tr\u00ean th\u1ecb tr\u01b0\u1eddng. H\u00ecnh d\u1ea1ng, v\u1eadt li\u1ec7u, \u0111\u1ed9 c\u1ee9ng, m\u00e0u s\u1eafc, dung sai, quy tr\u00ecnh ki\u1ec3m tra v\u00e0 \u0111\u00f3ng g\u00f3i \u0111\u01b0\u1ee3c ph\u00e1t tri\u1ec3n d\u1ef1a tr\u00ean b\u1ea3n v\u1ebd c\u1ee7a kh\u00e1ch h\u00e0ng v\u00e0 c\u00e1c \u0111i\u1ec1u ki\u1ec7n l\u1eafp r\u00e1p v\u00e0 s\u1eed d\u1ee5ng chi ti\u1ebft \u0111\u00f3. MadeForSilicone s\u1ebd xem x\u00e9t c\u00e1c d\u1eef li\u1ec7u 2D\/3D c\u00f3 s\u1eb5n tr\u01b0\u1edbc khi l\u1eadp b\u00e1o gi\u00e1 khu\u00f4n m\u1eabu v\u00e0 s\u1ea3n xu\u1ea5t.<\/p>\n<h2>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt ti\u00eau bi\u1ec3u c\u1ee7a s\u1ea3n ph\u1ea9m<\/h2>\n<table>\n<tbody>\n<tr>\n<th>S\u1ea3n ph\u1ea9m<\/th>\n<td>C\u00e1c b\u1ed9 ph\u1eadn c\u1ee7a thi\u1ebft b\u1ecb h\u00f4 h\u1ea5p \u0111\u01b0\u1ee3c \u0111\u00fac ph\u1ee7 b\u1eb1ng LSR<\/td>\n<\/tr>\n<tr>\n<th>L\u1ed9 tr\u00ecnh v\u1eadt li\u1ec7u<\/th>\n<td>Project-approved LSR over PC or other qualified engineering plastic<\/td>\n<\/tr>\n<tr>\n<th>Quy tr\u00ecnh \u0111\u00fac<\/th>\n<td>Insert molding and liquid silicone rubber overmolding<\/td>\n<\/tr>\n<tr>\n<th>T\u00f9y ch\u1ec9nh<\/th>\n<td>K\u00edch th\u01b0\u1edbc d\u1ef1a tr\u00ean b\u1ea3n v\u1ebd, \u0111\u1ed9 c\u1ee9ng, m\u00e0u s\u1eafc, b\u1ec1 m\u1eb7t, c\u00e1c \u0111\u1eb7c t\u00ednh ch\u1ee9c n\u0103ng v\u00e0 k\u1ebf ho\u1ea1ch ki\u1ec3m tra<\/td>\n<\/tr>\n<tr>\n<th>C\u00e1c \u1ee9ng d\u1ee5ng \u0111i\u1ec3n h\u00ecnh<\/th>\n<td>Nebulizer subassemblies, respiratory equipment, controlled fluid or air interfaces<\/td>\n<\/tr>\n<tr>\n<th>S\u1ed1 l\u01b0\u1ee3ng \u0111\u1eb7t h\u00e0ng t\u1ed1i thi\u1ec3u (MOQ)<\/th>\n<td>D\u1ef1a tr\u00ean d\u1ef1 \u00e1n; \u0111\u01b0\u1ee3c \u0111\u00e1nh gi\u00e1 d\u1ef1a tr\u00ean c\u00e1c y\u1ebfu t\u1ed1: d\u1ee5ng c\u1ee5 gia c\u00f4ng, v\u1eadt li\u1ec7u, quy tr\u00ecnh x\u1eed l\u00fd dao phay, ph\u1ea1m vi ki\u1ec3m tra v\u00e0 d\u1ef1 b\u00e1o \u0111\u01a1n h\u00e0ng<\/td>\n<\/tr>\n<tr>\n<th>\u0110\u1ecbnh d\u1ea1ng cung c\u1ea5p<\/th>\n<td>Linh ki\u1ec7n \u0111\u00fac theo y\u00eau c\u1ea7u, trong \u0111\u00f3 c\u00e1c c\u00f4ng \u0111o\u1ea1n gia c\u00f4ng th\u1ee9 c\u1ea5p ho\u1eb7c c\u1ee5m l\u1eafp r\u00e1p s\u1ebd \u0111\u01b0\u1ee3c xem x\u00e9t khi c\u00f3 y\u00eau c\u1ea7u c\u1ee5 th\u1ec3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Ki\u1ec3m tra k\u1ef9 thu\u1eadt v\u00e0 DFM<\/h2>\n<p>Medical-device subcomponents require the use condition and documentation scope to be defined before a mold is built. The review should identify whether the silicone contacts a fluid path, how the part is assembled, which surfaces are critical, what cleaning or processing exposure is expected and which material grade has been approved by the customer. Thin membranes, soft sealing lips, rigid-soft interfaces and cable transitions are evaluated for filling, venting, demolding and handling. Regulatory classification and final device compliance remain the customer\u2019s responsibility, while the component specification provides the measurable basis for manufacturing.<\/p>\n<p>For this lsr overmolded respiratory device components program, the first review compares the functional intent with the information listed in the RFQ. The engineering team then confirms which features are critical, which surfaces are cosmetic, where measurement datums should be placed and how the part can be removed from the mold without damaging thin or retained features. Any recommendation is returned for customer approval before tool manufacture.<\/p>\n<h3>C\u00e1c t\u00f9y ch\u1ecdn thi\u1ebft k\u1ebf c\u00f3 s\u1eb5n<\/h3>\n<ul>\n<li>Integrated seal around a rigid molded body<\/li>\n<li>Soft interfaces, ribs, valves or flexible connection features<\/li>\n<li>Transparent or colored components by requirement<\/li>\n<li>Assembly and functional checks defined with the customer<\/li>\n<\/ul>\n<h2>L\u1ef1a ch\u1ecdn v\u1eadt li\u1ec7u v\u00e0 quy tr\u00ecnh s\u1ea3n xu\u1ea5t<\/h2>\n<p>M\u00f4 t\u1ea3 s\u01a1 b\u1ed9 v\u1ec1 v\u1eadt li\u1ec7u l\u00e0 <strong>Project-approved LSR over PC or other qualified engineering plastic<\/strong>, v\u00e0 quy tr\u00ecnh s\u1ea3n xu\u1ea5t d\u1ef1 ki\u1ebfn l\u00e0 <strong>Insert molding and liquid silicone rubber overmolding<\/strong>. Nh\u1eefng th\u00f4ng tin n\u00e0y ch\u1ec9 l\u00e0 \u0111i\u1ec3m kh\u1edfi \u0111\u1ea7u, kh\u00f4ng th\u1ec3 thay th\u1ebf cho vi\u1ec7c xem x\u00e9t c\u00e1c y\u00eau c\u1ea7u v\u1ec1 nhi\u1ec7t \u0111\u1ed9, m\u00f4i tr\u01b0\u1eddng nu\u00f4i c\u1ea5y, v\u1ec7 sinh, chuy\u1ec3n \u0111\u1ed9ng, t\u1ea3i tr\u1ecdng, \u0111i\u1ec7n ho\u1eb7c ti\u1ebfp x\u00fac. C\u00e1c c\u1ea5p \u0111\u1ed9 ch\u00ednh x\u00e1c v\u00e0 b\u1ea5t k\u1ef3 t\u00e0i li\u1ec7u \u0111\u1eb7c bi\u1ec7t n\u00e0o \u0111\u1ec1u \u0111\u01b0\u1ee3c x\u00e1c nh\u1eadn trong b\u1ea3n \u0111\u1eb7c \u0111i\u1ec3m k\u1ef9 thu\u1eadt \u0111\u00e3 \u0111\u01b0\u1ee3c ph\u00ea duy\u1ec7t.<\/p>\n<p>LSR injection molding, precision compression molding or insert overmolding is selected according to geometry, material, volume and validation needs. Where plastic, cable or metal inserts are involved, exact substrate grades, surface condition, lot control and fixture references must be supplied. Cleanliness, packaging, material records and any special handling are quoted according to an agreed project specification; they are not assumed from the term \u201cmedical grade.\u201d Process parameters, cavity strategy and secondary operations are planned around the approved component drawing and sample criteria.<\/p>\n<h2>L\u1eadp k\u1ebf ho\u1ea1ch ch\u1ea5t l\u01b0\u1ee3ng v\u00e0 x\u00e1c nh\u1eadn d\u1ef1 \u00e1n<\/h2>\n<p>Inspection planning can include critical dimensions, membrane or slit condition, flash and surface limits, insert position, assembly fit and a project-specific functional test. Examples include leak, opening pressure, flow, pull, flex or visual criteria, but the relevant method depends on the component. Sampling level, report format, traceability, packaging and retained samples are established by agreement so the quotation reflects the actual program rather than a generic medical claim.<\/p>\n<p>For LSR Overmolded Respiratory Device Components, a practical control plan may cover the following items. Final limits, gauges, fixtures and sampling frequency are established from the customer drawing, approved samples and purchase requirements.<\/p>\n<ul>\n<li>Critical dimensions, thin features and sealing surfaces<\/li>\n<li>Flash, cosmetic condition and insert-position review<\/li>\n<li>Project-defined leak, flow, pull, flex or assembly test<\/li>\n<li>Material, lot, report and packaging records by agreement<\/li>\n<\/ul>\n<h2>Quy tr\u00ecnh s\u1ea3n xu\u1ea5t v\u00e0 ch\u1ebf t\u1ea1o khu\u00f4n m\u1eabu theo m\u00f4 h\u00ecnh OEM\/ODM<\/h2>\n<p>Quy tr\u00ecnh d\u1ef1 \u00e1n th\u00f4ng th\u01b0\u1eddng bao g\u1ed3m: r\u00e0 so\u00e1t b\u1ea3n v\u1ebd, l\u00e0m r\u00f5 c\u00e1c v\u1ea5n \u0111\u1ec1 k\u1ef9 thu\u1eadt, b\u00e1o gi\u00e1, x\u00e1c nh\u1eadn DFM, ch\u1ebf t\u1ea1o khu\u00f4n m\u1eabu, l\u1ea5y m\u1eabu s\u1ea3n ph\u1ea9m \u0111\u1ea7u ti\u00ean, \u0111\u00e1nh gi\u00e1 c\u1ee7a kh\u00e1ch h\u00e0ng v\u00e0 s\u1ea3n xu\u1ea5t h\u00e0ng lo\u1ea1t c\u00f3 ki\u1ec3m so\u00e1t. Khi c\u00f3 s\u1eb5n m\u1eabu v\u1eadt l\u00fd, m\u1eabu n\u00e0y c\u00f3 th\u1ec3 h\u1ed7 tr\u1ee3 qu\u00e1 tr\u00ecnh r\u00e0 so\u00e1t, nh\u01b0ng v\u1eabn n\u00ean s\u1eed d\u1ee5ng b\u1ea3n v\u1ebd \u0111\u01b0\u1ee3c ph\u00ea duy\u1ec7t cho c\u00e1c \u0111\u01a1n h\u00e0ng ti\u1ebfp theo. Gi\u00e1 khu\u00f4n v\u00e0 gi\u00e1 \u0111\u01a1n v\u1ecb s\u1ebd \u0111\u01b0\u1ee3c x\u00e1c \u0111\u1ecbnh sau khi \u0111\u00e3 n\u1eafm r\u00f5 th\u00f4ng tin v\u1ec1 v\u1eadt li\u1ec7u, chi\u1ebfn l\u01b0\u1ee3c khu\u00f4n, c\u00e1c c\u00f4ng \u0111o\u1ea1n gia c\u00f4ng th\u1ee9 c\u1ea5p, ph\u1ea1m vi ki\u1ec3m tra v\u00e0 d\u1ef1 b\u00e1o kh\u1ed1i l\u01b0\u1ee3ng s\u1ea3n xu\u1ea5t. Do \u0111\u00f3, th\u1eddi gian ho\u00e0n thi\u1ec7n m\u1eabu th\u1eed v\u00e0 s\u1ea3n xu\u1ea5t ph\u1ee5 thu\u1ed9c v\u00e0o h\u00ecnh d\u1ea1ng th\u1ef1c t\u1ebf v\u00e0 k\u1ebf ho\u1ea1ch ph\u00ea duy\u1ec7t, ch\u1ee9 kh\u00f4ng ph\u1ea3i d\u1ef1a tr\u00ean th\u1eddi gian giao h\u00e0ng chung trong danh m\u1ee5c s\u1ea3n ph\u1ea9m.<\/p>\n<p>Sau khi nh\u1eadn \u0111\u01b0\u1ee3c ph\u1ea3n h\u1ed3i v\u1ec1 m\u1eabu th\u1eed, c\u00e1c thay \u0111\u1ed5i \u0111\u00e3 \u0111\u01b0\u1ee3c th\u1ed1ng nh\u1ea5t s\u1ebd \u0111\u01b0\u1ee3c ghi l\u1ea1i tr\u01b0\u1edbc khi ti\u1ebfn h\u00e0nh \u0111\u1ee3t th\u1eed nghi\u1ec7m ti\u1ebfp theo ho\u1eb7c \u0111\u01b0a v\u00e0o s\u1ea3n xu\u1ea5t h\u00e0ng lo\u1ea1t. C\u00e1c \u0111\u1eb7c t\u00ednh quan tr\u1ecdng c\u00f3 th\u1ec3 \u0111\u01b0\u1ee3c li\u00ean k\u1ebft v\u1edbi b\u00e1o c\u00e1o ki\u1ec3m tra, khu\u00f4n l\u1eafp r\u00e1p ho\u1eb7c b\u00e0i ki\u1ec3m tra ch\u1ee9c n\u0103ng theo th\u1ecfa thu\u1eadn c\u1ee7a d\u1ef1 \u00e1n. C\u00e1ch ti\u1ebfp c\u1eadn n\u00e0y gi\u00fap c\u00e1c b\u1ed9 ph\u1eadn mua h\u00e0ng, k\u1ef9 thu\u1eadt v\u00e0 ch\u1ea5t l\u01b0\u1ee3ng c\u00f3 chung m\u1ed9t b\u1ea3n \u0111\u1eb7c \u0111i\u1ec3m k\u1ef9 thu\u1eadt khi chi ti\u1ebft chuy\u1ec3n t\u1eeb giai \u0111o\u1ea1n ph\u00e1t tri\u1ec3n sang giai \u0111o\u1ea1n s\u1ea3n xu\u1ea5t h\u00e0ng lo\u1ea1t.<\/p>\n<h2>C\u00e1c t\u00ecnh hu\u1ed1ng \u1ee9ng d\u1ee5ng<\/h2>\n<p>These parts are intended for qualified B2B development programs such as diagnostic, respiratory, fluid-handling and monitoring subassemblies, not for direct retail or an unspecified finished medical device. Typical uses for this product family include:<\/p>\n<ul>\n<li>Nebulizer subassemblies<\/li>\n<li>respiratory equipment<\/li>\n<li>controlled fluid or air interfaces<\/li>\n<\/ul>\n<h2>Th\u00f4ng tin c\u1ea7n n\u00eau trong y\u00eau c\u1ea7u b\u00e1o gi\u00e1 (RFQ) c\u1ee7a b\u1ea1n<\/h2>\n<ul>\n<li>Rigid insert drawing and resin specification<\/li>\n<li>Flow path, sealing surfaces and mating parts<\/li>\n<li>Use, cleaning and compliance requirements<\/li>\n<li>Critical dimensions, tests and expected order volume<\/li>\n<\/ul>\n<p>Xin vui l\u00f2ng n\u00eau r\u00f5 s\u1ed1 l\u01b0\u1ee3ng m\u1eabu th\u1eed, s\u1ed1 l\u01b0\u1ee3ng \u0111\u01a1n h\u00e0ng \u0111\u1ea7u ti\u00ean v\u00e0 nhu c\u1ea7u \u01b0\u1edbc t\u00ednh h\u00e0ng n\u0103m. N\u1ebfu m\u1ed9t y\u00eau c\u1ea7u v\u1eabn \u0111ang trong giai \u0111o\u1ea1n ph\u00e1t tri\u1ec3n, h\u00e3y x\u00e1c \u0111\u1ecbnh \u0111\u00f3 l\u00e0 m\u1ee5c ti\u00eau \u0111\u1ec3 c\u00f3 th\u1ec3 ph\u00e2n bi\u1ec7t v\u1edbi ti\u00eau ch\u00ed ch\u1ea5p nh\u1eadn ch\u1eafc ch\u1eafn. C\u00e1c b\u1ea3n v\u1ebd v\u00e0 m\u00f4 h\u00ecnh \u0111\u01b0\u1ee3c coi l\u00e0 th\u00f4ng tin d\u1ef1 \u00e1n v\u00e0 \u0111\u01b0\u1ee3c s\u1eed d\u1ee5ng \u0111\u1ec3 \u0111\u00e1nh gi\u00e1 kh\u1ea3 n\u0103ng s\u1ea3n xu\u1ea5t, v\u1eadt li\u1ec7u, d\u1ee5ng c\u1ee5 gia c\u00f4ng v\u00e0 c\u00e1c y\u00eau c\u1ea7u ki\u1ec3m tra.<\/p>\n<h2>C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3>MadeForSilicone c\u00f3 th\u1ec3 t\u00f9y ch\u1ec9nh s\u1ea3n ph\u1ea9m n\u00e0y d\u1ef1a tr\u00ean b\u1ea3n v\u1ebd ho\u1eb7c m\u1eabu c\u1ee7a t\u00f4i kh\u00f4ng?<\/h3>\n<p>Yes. LSR Overmolded Respiratory Device Components is developed from customer requirements. A 3D model plus a toleranced 2D drawing gives the clearest basis for tooling and inspection. A physical sample or mating component can help us understand fit and function, but dimensions, material and acceptance tests should be documented before repeat production.<\/p>\n<h3>C\u00f3 nh\u1eefng l\u1ef1a ch\u1ecdn v\u1ec1 ch\u1ea5t li\u1ec7u v\u00e0 ki\u1ec3u d\u00e1ng n\u00e0o?<\/h3>\n<p>The initial route is project-approved lsr over pc or other qualified engineering plastic. Options can include integrated seal around a rigid molded body and soft interfaces, ribs, valves or flexible connection features. The final combination is selected after the operating environment, mating parts and validation method are reviewed; no material grade or compliance claim is assumed without a project specification.<\/p>\n<h3>Y\u1ebfu t\u1ed1 n\u00e0o quy\u1ebft \u0111\u1ecbnh chi ph\u00ed khu\u00f4n m\u1eabu, s\u1ed1 l\u01b0\u1ee3ng \u0111\u1eb7t h\u00e0ng t\u1ed1i thi\u1ec3u (MOQ) v\u00e0 th\u1eddi gian s\u1ea3n xu\u1ea5t?<\/h3>\n<p>C\u00e1c y\u1ebfu t\u1ed1 ch\u00ednh bao g\u1ed3m k\u00edch th\u01b0\u1edbc v\u00e0 \u0111\u1ed9 ph\u1ee9c t\u1ea1p c\u1ee7a chi ti\u1ebft, s\u1ed1 l\u01b0\u1ee3ng khu\u00f4n, c\u00e1c chi ti\u1ebft c\u00f3 r\u00e3nh c\u1eaft s\u00e2u ho\u1eb7c chi ti\u1ebft ch\u00e8n, v\u1eadt li\u1ec7u \u0111\u01b0\u1ee3c l\u1ef1a ch\u1ecdn, c\u00e1c c\u00f4ng \u0111o\u1ea1n gia c\u00f4ng th\u1ee9 c\u1ea5p, thi\u1ebft b\u1ecb ki\u1ec3m tra, s\u1ed1 l\u01b0\u1ee3ng m\u1eabu v\u00e0 d\u1ef1 b\u00e1o kh\u1ed1i l\u01b0\u1ee3ng s\u1ea3n xu\u1ea5t. Do \u0111\u00f3, s\u1ed1 l\u01b0\u1ee3ng \u0111\u1eb7t h\u00e0ng t\u1ed1i thi\u1ec3u (MOQ) s\u1ebd \u0111\u01b0\u1ee3c x\u00e1c \u0111\u1ecbnh t\u00f9y theo t\u1eebng d\u1ef1 \u00e1n. Vui l\u00f2ng g\u1eedi th\u00f4ng tin y\u00eau c\u1ea7u b\u00e1o gi\u00e1 (RFQ) n\u00eau tr\u00ean, v\u00e0 ch\u00fang t\u00f4i s\u1ebd chu\u1ea9n b\u1ecb \u0111\u1ec1 xu\u1ea5t s\u1ea3n xu\u1ea5t c\u00f9ng b\u00e1o gi\u00e1 \u0111\u1ec3 qu\u00fd c\u00f4ng ty xem x\u00e9t v\u1ec1 m\u1eb7t k\u1ef9 thu\u1eadt v\u00e0 mua h\u00e0ng.<\/p>","protected":false},"excerpt":{"rendered":"<p>C\u00e1c b\u1ed9 ph\u1eadn con c\u1ee9ng-m\u1ec1m cho c\u00e1c c\u1ee5m thi\u1ebft b\u1ecb h\u00f4 h\u1ea5p v\u00e0 x\u1eed l\u00fd ch\u1ea5t l\u1ecfng, \u0111\u01b0\u1ee3c s\u1ea3n xu\u1ea5t b\u1eb1ng ph\u01b0\u01a1ng ph\u00e1p \u0111\u00fac ph\u1ee7 LSR \u0111\u00e3 \u0111\u01b0\u1ee3c ph\u00ea duy\u1ec7t.<\/p>","protected":false},"featured_media":2307,"template":"","meta":[],"product_brand":[],"product_cat":[2001],"product_tag":[],"class_list":["post-2107","product","type-product","status-publish","has-post-thumbnail","product_cat-medical","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/product\/2107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/media\/2307"}],"wp:attachment":[{"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/media?parent=2107"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2107"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2107"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.madeforsilicone.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}