Built for medical nebulizer systems, respiratory therapy devices, and inhalation drug delivery equipment, Medical LSR Overmolded Nebulizer Cup with PC Housing is a medical and healthcare silicone component centered on material system: Liquid Silicone Rubber + Polycarbonate; process: Two-Shot Injection Molding (LSR Over PC); base material: Medical Grade PC. This configuration is intended for buyers who need a production-ready part rather than a generic off-the-shelf silicone item.
Pour les programmes OEM et sur mesure, les questions pratiques portent sur l'ajustement de la pièce, les contraintes auxquelles elle doit résister et les dimensions ou interfaces critiques. Les sections suivantes classent les exigences de performance, les informations relatives aux matériaux et aux procédés, ainsi que les détails d'application, afin de permettre une évaluation plus efficace du produit.
Priorités en matière de conception fonctionnelle
- The overmolded silicone material is specially formulated for medical applications. It offers excellent biocompatibility and is suitable for inhalation-related environments.
- ISO 10993 biocompatibility compliant
- USP Class VI certified material
- Odorless, non-toxic, and stable under long-term use
- Developed for direct or indirect patient contact
- The LSR is permanently bonded to the PC substrate through precision injection molding, forming a seamless sealing interface.
- Eliminates traditional O-rings and manual assembly
Configuration technique
| Nom du produit | LSR Overmolded PC Nebulizer Cup |
|---|---|
| Material System | Liquid Silicone Rubber + Polycarbonate |
| Processus | Two-Shot Injection Molding (LSR Over PC) |
| Base Material | Medical Grade PC |
| Overmold Material | Medical Grade LSR |
| Transparency | High optical clarity |
| Temperature Resistance | -40°C to 134°C |
| Sterilization Methods | Autoclave, EO, Gamma |
| Biocompatibility | ISO 10993 / USP Class VI |
| Structure Type | Soft-hard integrated sealing component |
| Reusability | Designed for repeated use |
Where the Part Is Used
- Medical nebulizer systems
- Respiratory therapy devices
- Inhalation drug delivery equipment
- ICU respiratory support systems
- Home healthcare nebulization devices
- Medical gas and fluid control systems
Design Notes for Production
- The product is produced through a precision two-step injection molding process:
- PC Injection Molding Medical-grade polycarbonate is molded into the structural base, forming the rigid housing and internal flow channels.
- LSR Overmolding Liquid silicone rubber is injected onto the PC substrate, forming soft sealing structures and functional interfaces.
- Permanent Bonding Formation Under controlled temperature and pressure, LSR chemically or mechanically bonds with PC, forming a durable integrated structure.
- Silicone rubber has natural chemical inertness, making adhesion to PC challenging. This is solved through:
- Self-bonding medical-grade LSR formulations
FAQ for Engineering Buyers
What is the benefit of LSR overmolding compared to traditional assembly?
LSR overmolding eliminates separate sealing components such as O-rings, reducing leakage risk and improving long-term stability.
Is the product suitable for repeated sterilization?
Yes, it is designed for repeated autoclave sterilization between 121°C and 134°C without performance degradation.
Does the silicone become hard or degrade over time?
Medical-grade LSR maintains elasticity and mechanical stability under long-term use.
Examen des appels d'offres et des plans
La mise en production doit se fonder sur le dessin définitif et les exigences d'application, plutôt que sur la seule description figurant dans le catalogue. Les spécifications ci-dessus peuvent servir de référence pour valider les dimensions, les interfaces et les performances attendues de la pièce sur mesure.